The Polydeck® 165SC Pedestrian Traffic Deck System is a liquid applied, polyurethane waterproofing deck system. The system utilizes an epoxy primer, one coat of a fast setting water catalyzed polyurethane basecoat with a rubber aggregate that can be applied at any thickness, and one or two coats of an aliphatic polyurethane topcoat.

Material Use:

 Polydeck 165SC is a liquid-applied, polyurethane-based waterproofing pedestrian traffic deck system designed to protect concrete and plywood substrates. It offers high flexibility and durability against weather, chemicals, spalling, and freeze/thaw damage, while accommodating structural movements.

System Components:

·       Primer: Polyprime 2180SC (for metal and general surfaces), Polyprime EBF-LV (for porous or outgassing concrete)

·       Basecoat: PC-550SC (water-catalyzed polyurethane with rubber aggregate)

·       Topcoat: Polyglaze 100/100SC/100C or Polyglaze AL-50/AL-50SC (aliphatic polyurethane)

Applications:

 Ideal for use on balconies, patios, roof decks, sun decks, walkways, and areas over occupied space.

Application Details:

·       Priming:

o   Polyprime 2180SC: 1 gal/300 sq ft (3 dry mils)

o   Polyprime EBF-LV (for rough/porous concrete): 1 gal/200 sq ft

·       Basecoat (PC-550SC):

o   Rubber finish: 4 gal/100 sq ft (58 dry mils)

o   Sand finish: 3 gal/100 sq ft + 1 gal/100 sq ft second coat (total 57 dry mils)

·       Aggregate Broadcast:

o   Rubber granules: 10 lbs/100 sq ft

o   Sand (20 mesh, Moh’s 6.5+): 20 lbs/100 sq ft

·       Topcoat (Polyglaze): 1.25 gal/100 sq ft (13–14 dry mils)

·       Full System Thickness: 72 dry mils (1836 microns), exclusive of aggregate

·       Fast Cure Option: Polyglaze Hardener reduces cure time to 2–4 hours per coat; recoats within 8–12 hours

Special Notes:

·       Not suitable for below-grade slabs, unvented metal pans, magnesite, asphalt, lightweight concrete, or pool decks.

·       Concrete must be 3000 psi minimum and cured for 28 days.

·       Must be applied >5°F above dew point.

·       Substrate must be sound and properly sloped for drainage.

·       Pot life and working time depend on ambient temperature; details in individual component TDS recommended.

·       Uncured materials are moisture and heat-sensitive.

·       Coverage and thickness are lab-tested on smooth substrates; mockups are advised for accurate project-specific measurements.

·       Cleaning: Use urethane-grade environmentally safe solvents immediately after application.

UV Stability:
 Polyglaze topcoats are aliphatic polyurethanes, which are UV stable, ensuring long-term exposure resistance.

https://www.polycoatusa.com/system.php?systemName=Polydeck%C2%AE%20165/165SC

Payment & Security

American Express Apple Pay Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed