Description
KEMKO 068 LO VIS IR – Low Viscosity Structural Epoxy Adhesive. KEMKO 068 is designed for structural repair by pressure injection grouting. It is primarily used for injecting fine cracks (as narrow as 2 mils / 0.05 mm) in concrete, masonry, stone, and wood. This epoxy also serves in applications requiring high load-bearing strength, adhesion in wet or cold conditions, and resistance to creep and stress relaxation.
KEMKO 068 is a two-component epoxy (Part A resin and Part B hardener) used with the proprietary KIP (KEMKO Injection Process) System for automatic meter-mix-dispense application. It is a part of a specialized system available only through certified KEMKO applicators. When used for large voids (>1/4 inch or 6.35 mm), uniform-sized aggregate must be pre-placed to prevent excess heat generation during cure.
· Structural repair of cracks and delaminations in concrete, masonry, wood
· Filling of porous or honeycombed concrete and grout
· Bonding steel plates and CFRP (carbon fiber reinforced polymer) for external reinforcement
· Anchoring bolts, dowels, and rebar
· Grouting tight voids under equipment
· May be used as a Healer/Sealer (KEMKO 186 preferred when time permits)
· Installation Method: Pressure injection using KIP System
· Mix Ratio: 2:1 by volume (100:43 by weight)
· Color: Dark purple mixed (clear amber option available)
· Viscosity: 200 cps (mixed), increases to 1,150 cps @ 40°F (4°C)
· Pot Life (Gel Time): 21 minutes at 73°F (23°C), 85 minutes at 40°F (4.4°C)
· Bond Strength (Wet): 3,600 psi (2 days), 3,700 psi (14 days)
· Coverage: Not explicitly listed; dependent on crack volume and substrate porosity
· Mixing: For use with KIP System only
· Surface Prep: Follows ICRI Guideline 310.2R and SSPC-SP 5 for steel
· Cure Conditions: Minimum substrate temperature 40°F (4.4°C); not to be thinned or mixed outside of prescribed ratio
· Full Cure: Not explicitly specified, though compressive strength data is based on 7-day cure at 73°F
· Chemical Resistance: Excellent to acids, bases, fuels, oils; limited against hydrocarbon solvents
· UV Resistance: Not UV stable; intended for internal or covered applications
· Service Temperature Limit: Max service temp should be at least 20°F below HDT (140°F / 60°C)
· Compatibility: Can bond to dry, damp, wet, and underwater substrates
· Alternative/Complementary Materials:
o KEMKO 186 – Preferred for Healer/Sealer applications
o KEMKO 038 IR – For wider cracks (6 mils to 1/4")
o KEMKO 322 ULV IR – For low temps or very fine cracks
o KEMKO 030 HiAmb IR – For temps above 90°F (32.2°C)
o KEMKO 077 – For large voids
o KEMKO 050 – For cracks with no rear seal access